Choose a category

 

Catalogues

 

 

Loox LED Lighting Systems

 

Bathex Fittings For The Disabled

 

Green Eco Friendly

Progeny P3 access controller

Progeny P3 access controller
Loading image...

Progeny P3 access controller
• Can be programmed via keypad and from a PC:
Keypad gives access to all user and engineering menu functions, so controller can be installed and operational even before network and PC are available
No dependance on central hardware for operation - all controllers will continue to work even if isolated from PC or network
• Suits small to large systems; small systems can be expanded into large systems to keep up with changing requirements
• Contoller box dimensions (height x width x depth): 308 x 320 x 78 mm
• Multi site access control system for up to:
- 10,000 sites
- 65,000 doors
- 10,000 card holders
• Simple system architecture
• Power supply:
- Supply voltage in: 230 V AC
- Supply power: 60VA
- Battery charger: Sealed lead acid 12V or 24V 7Ahr
- Lock outputs: 12V/24V
• Relay outputs:
- Lock output relay: 12 or 24V DC applied and removed
- Relay B contact ratings: 3.0 Amps at 30V DC
- Relay B modes: 9 slave functions
- Lock timer: 1 to 99 seconds, 0 = toggle mode
- Anti tailgate feature as standard
• Inputs:
- Request to exit input: Normally open contact
- Door monitor input: Closed contact when door closed
- Auxiliary: Fire, intruder, tamper
• Alarms: prolonged door open, door forced, hacker, duress
• P3 connectivity:
- PC cable connects a PC to any of the controllers on the network - order separately
- Uses local or wide area network (LAN or WAN)
- Modem links to remote sites possible
• Random card facility
• User definable 4 digit PIN codes
- 2 to 6 digit length access codes
• 2,000 event memory per door, selective event reporting
• Door monitoring and interlocking
• 255 time zone windows can be applied to doors or access levels - doors can be given periods of ‘free vend’ or be switched from ‘card only’ to card and PIN’ based on the time of day and day or week
• System integration with Time and Attendance or HR databases, Fire systems etc.
• Network: Half duplex RS 485 (2 wire) with Belden 8133 or 8132 (1 m max.) cables
• Roll call manual or automatic to multiple printers
• Doors enterprise software must be ordered separately
Card and readers type: Magstripe, Barcode, Proximity and Biometric all possible - P3 will interface to 35 standard reader technologies, custom formats can also be definied through the advanced engineers menu
Two reader inputs: ‘card in’, ‘card out’ or dual height Reader supplies: 12V @ 500mA current limited, 5V 100 mA current limited
6 core screened cables (100 m max.)

 

Code: 912.09.302

Product Information Sheetview PDF

Buying this product will earn 9025 Loyalty Points.
Collected points can be redeemed against future purchases!
More info. »

ALL PRICES SHOWN ARE INCLUSIVE OF VAT

Our price £902.49*

Pack Qty 1 Piece

Out of stock

Check stock availability
Overnight stock level - 0 in stock*


* Please note that our stock figures are updated once every 24 hours and should be used as a guide only.

Whilst we do keep some stock at our warehouse, much of it is kept at our central warehouse in Rugby.
PLEASE CONTACT US TO CHECK BEFORE VISITING.

 
» View illustration
 

Description

Progeny P3 access controller
• Can be programmed via keypad and from a PC:
Keypad gives access to all user and engineering menu functions, so controller can be installed and operational even before network and PC are available
No dependance on central hardware for operation - all controllers will continue to work even if isolated from PC or network
• Suits small to large systems; small systems can be expanded into large systems to keep up with changing requirements
• Contoller box dimensions (height x width x depth): 308 x 320 x 78 mm
• Multi site access control system for up to:
- 10,000 sites
- 65,000 doors
- 10,000 card holders
• Simple system architecture
• Power supply:
- Supply voltage in: 230 V AC
- Supply power: 60VA
- Battery charger: Sealed lead acid 12V or 24V 7Ahr
- Lock outputs: 12V/24V
• Relay outputs:
- Lock output relay: 12 or 24V DC applied and removed
- Relay B contact ratings: 3.0 Amps at 30V DC
- Relay B modes: 9 slave functions
- Lock timer: 1 to 99 seconds, 0 = toggle mode
- Anti tailgate feature as standard
• Inputs:
- Request to exit input: Normally open contact
- Door monitor input: Closed contact when door closed
- Auxiliary: Fire, intruder, tamper
• Alarms: prolonged door open, door forced, hacker, duress
• P3 connectivity:
- PC cable connects a PC to any of the controllers on the network - order separately
- Uses local or wide area network (LAN or WAN)
- Modem links to remote sites possible
• Random card facility
• User definable 4 digit PIN codes
- 2 to 6 digit length access codes
• 2,000 event memory per door, selective event reporting
• Door monitoring and interlocking
• 255 time zone windows can be applied to doors or access levels - doors can be given periods of ‘free vend’ or be switched from ‘card only’ to card and PIN’ based on the time of day and day or week
• System integration with Time and Attendance or HR databases, Fire systems etc.
• Network: Half duplex RS 485 (2 wire) with Belden 8133 or 8132 (1 m max.) cables
• Roll call manual or automatic to multiple printers
• Doors enterprise software must be ordered separately
Card and readers type: Magstripe, Barcode, Proximity and Biometric all possible - P3 will interface to 35 standard reader technologies, custom formats can also be definied through the advanced engineers menu
Two reader inputs: ‘card in’, ‘card out’ or dual height Reader supplies: 12V @ 500mA current limited, 5V 100 mA current limited
6 core screened cables (100 m max.)

Customer reviews

This product does not currently have any reviews.

Be the first to submit a review for the Progeny P3 access controller.

12345